Product Info:
Product Presentations
Product Literature
Locate Distributors
About McKeon

Fire & Smoke Rated
Doors and Shutters
with emergency egress:

Vertical Coiling
Vertical Acting
Side Coiling
Side Acting
Accordion Doors
without emergency egress:
Horizontal Shutters
Side Coiling
Overhead Coiling
Insulated
Acoustical
Counter Shutters
The Retrofit Option
for Rolling Fire Doors
McKeon has UL Classification and FM Approval to retrofit most existing rolling fire doors, regardless of original manufacturer...
MORE INFORMATION

Non Fire-Rated
Service Doors & Grilles
Self-Opening Vertical
Self-Opening, Side Coil
Side Coil Doors & Grilles
Service Doors
Perforated Doors
Insulated Doors
Hurricane Doors
Security Grilles
Counter Shutters
Horizontal Coiling Doors
The Retrofit Option for Rolling Fire Doors

Introduction | The Problems With Conventional Doors | Tested and Approved
Installation | Significant Advantages to Building Owners



Download McKeon 6-Page Retrofit Brochure: McKeon-Retrofit.pdf (354 Kb)



The Problems With Conventional Doors . . .

Testing Difficulty | Inadequate Maintenance | Damage

Improper Installation | Manufacturing Quality | Occupancy Related


 IMPROPER INSTALLATION
Fire door malfunctions often originate during installation, as a result of inexperienced installers and poorly prepared installation instructions.

THE AUTO-SET® SOLUTION: Fire doors should be designed in a manner allowing for easy testing and resetting verifying that the door was installed correctly and will function properly when the need arises. The Auto-Set ® System is designed for daily testing and resetting.
 MANUFACTURING QUALITY (DEFECTIVE PARTS)
Manufacturing defects in the external gears and mechanical governors which are inherent with the conventional fire door design can result in unpredictable and hazardous conditions.
THE AUTO-SET® SOLUTION: The Auto-Set® System has eliminated all the external parts which are prone to malfunction on conventional fire doors. The Auto-Set® System has been tested by Factory Mutual Research Corporation, for 50,000 operational cycles and 525 drop tests. Conventional fire doors are tested for 7,500 operational cycles and 25 drop tests.
 OCCUPANCY RELATED — (BLOCKED and WEDGED DOORS)
Fire doors are blocked and wedged by occupants of the building because they have been trip tested and not reset.
The occupant has wedged them in order to provide access through the opening.
Fire doors are blocked by material or fork trucks which are placed in the openings.

THE AUTO-SET® SOLUTION:
The Auto-Set® System automatically resets itself. Therefore, the possibility of an Auto-Set® door being tripped and not reset has been eliminated. If blocked doors has been a problem, McKeon Door will provide a detection system which will set off an audible alarm if the opening is blocked for a period of more than two minutes. In addition to this detection system, we recommend that the opening be clearly marked and signs posted stating that material cannot be placed under the fire door.

  
This product is covered under US Patents:
5,203,392 - 5,245,879 - 5,386,891 - 5,605,185 - 5,673,514 - 5,893,234 - 5,355,741 - 5,743,320

McKeon Rolling Steel Door Co., Inc. designs and manufactures fire and smoke rated doors, weather doors, acoustic doors as well as side acting security grilles. McKeon can produce rolling doors to your specifications. Contact us with your requirements.



McKeon Rolling Steel Door Co., Inc. · 44 Sawgrass Drive, Bellport, NY 11713 USA

Toll Free: 800-266-9392 · Tel: 631-803-3000 · Fax: 631-803-3030
info@McKeonDoor.com
Contents Copyright© 2000-2008 McKeon Rolling Steel Door Co., Inc. All rights reserved.